Prevention Measures for Centrifugal Pump Cavitation
Sep 25, 2025
In the previous section, we discussed the causes of centrifugal pump cavitation. Below, Anhui Shengshi Datang will introduce measures to prevent centrifugal pump cavitation.
1. Improvements in Design and Materials
From the perspectives of design and materials, the following measures can be taken to prevent or mitigate the hazards of centrifugal pump cavitation:
A. Gap Optimization Design: Appropriately increase the clearance between moving parts, especially between the impeller and the pump casing, and between the seal ring and the shaft, to reduce the risk of seizing due to thermal expansion. Research shows that increasing the standard clearance by 15%-20% can significantly reduce the probability of seizing during cavitation, with minimal impact on pump efficiency.
B. Material Selection and Treatment:
a. Perform tempering heat treatment on the pump shaft to improve its hardness and wear resistance, reducing deformation and wear during cavitation.
b. Select materials with low thermal expansion coefficients, such as stainless steel or special alloys, to minimize clearance changes caused by thermal expansion.
c. Apply wear-resistant coatings like hard alloy or use ceramic materials for key friction parts such as seal rings to enhance wear resistance.
C. Sealing System Improvements:
a. Use mechanical seals that do not rely on the pumped medium for lubrication, such as gas-lubricated mechanical seals or double mechanical seals.
b. Configure external lubrication systems to provide lubrication for the seal faces even when the pump is cavitating.
c. For packing seals, use self-lubricating packing, such as composite packing containing PTFE.
D. Bearing System Optimization:
a. Use enclosed self-lubricating bearings to reduce dependence on external cooling.
b. Add independent cooling systems for bearings to ensure normal bearing temperature is maintained even during pump cavitation.
c. Select bearings and lubricants with higher temperature tolerance.
E. Pump Cavity Design Improvements:
a. For special applications, design a water storage space so that the pump can maintain a minimum liquid volume even during short-term water shortage.
b. Self-priming pumps are typically designed with a larger pump cavity volume and specialized gas-liquid separation devices, allowing them to better handle short-term cavitation.
Practice shows that reasonable design and material selection can reduce the risk of damage during centrifugal pump cavitation by over 50%, while also extending the overall service life of the equipment.
2. Application of Monitoring and Control Systems
Modern monitoring and control technologies provide effective means to prevent centrifugal pump cavitation:
A. Cavitation Detection Systems:
a. Flow Monitoring: Install a flow meter at the pump outlet to automatically alarm or shut down the pump when the flow rate falls below a set value.
b. Current Monitoring: Motor load decreases during cavitation, leading to a significant drop in current; cavitation can be detected by monitoring current changes.
c. Pressure Monitoring: A sudden drop or increased fluctuation in outlet pressure is a key indicator of cavitation.
d. Temperature Monitoring: Abnormal temperature rises in mechanical seals, bearings, or the pump body can indirectly reflect the cavitation state.
B. Liquid Level Control Systems:
a. Install level sensors in water tanks, sumps, and other intake facilities to automatically stop the pump when the level falls below a safe value.
b. For special occasions, set up dual-level protection: low-level alarm and very low-level forced pump shutdown.
c. Use non-contact level gauges (e.g., ultrasonic, radar) to avoid potential jamming issues associated with traditional float switches.
C. Integrated Intelligent Control Systems:
a. Integrate multiple parameters (flow, pressure, temperature, level) into a PLC or DCS system to more accurately identify cavitation status through logical judgment.
b. Set up two levels of protection: cavitation warning and cavitation alarm. The system can attempt to automatically adjust operating conditions during a warning and force a shutdown during an alarm.
c. Use expert systems or artificial intelligence technology to predict potential cavitation risks in advance through historical data analysis.
D. Remote Monitoring and Management:
a. Utilize IoT technology to achieve remote monitoring of pump stations, enabling timely detection of abnormalities.
b. Establish fault prediction models to provide early warnings of potential cavitation risks through big data analysis.
c. Set up automatic recording and reporting systems to log changes in operating parameters, providing a basis for fault analysis.
Data shows that centrifugal pumps equipped with modern monitoring and control systems experience over 85% fewer cavitation incidents compared to traditional equipment, with significantly reduced maintenance costs. The value of these systems is particularly evident in unattended pump stations.
3. Operating Procedures and Maintenance Management
Scientific operating procedures and maintenance management are crucial links in preventing centrifugal pump cavitation:
A. Pre-Startup Checks and Preparation:
a. Confirm that valves on the suction line are fully open and filters are not clogged.
b. Check the sealing of the pump casing and pipelines to ensure there are no air leakage points.
c. Ensure the pump is fully primed and air is completely vented before the first startup or after a prolonged shutdown.
d. Manually rotate the pump shaft several turns to ensure it rotates flexibly without abnormal resistance.
B. Correct Startup and Shutdown Procedures:
a. Open the suction valve first, then the discharge valve, avoiding starting against a closed discharge valve.
b. For large pumps, start with the discharge valve slightly open, then fully open it once operation stabilizes.
c. When stopping the pump, close the discharge valve first, then the motor, and finally the suction valve to prevent backflow and water hammer.
d. Drain liquid from the pump casing promptly after shutdown in cold winter regions to prevent freezing.
C. Monitoring and Management During Operation:
a. Establish an operating log system to regularly record parameters such as flow, pressure, temperature, and current.
b. Implement an inspection round system to promptly detect abnormal noise, vibration, or leaks.
c. Avoid prolonged operation at low flow rates; install a minimum flow bypass line if necessary.
d. For multi-pump parallel systems, ensure reasonable load distribution among pumps to avoid single pump overload or cavitation.
D. Regular Maintenance and Inspection:
a. Regularly clean suction line filters to prevent clogging.
b. Check the condition of mechanical seals or packing seals, and replace aged or damaged parts promptly.
c. Regularly check bearing temperature and lubrication status, adding or replacing lubricant as required.
d. Periodically measure seal ring clearances to ensure they are within allowable limits.
e. Check that balance pipes and balance holes are clear (applicable to multi-stage pumps).
E. Personnel Training and Management:
a. Provide professional training for operators and maintenance personnel to improve their ability to identify and handle faults.
b. Formulate clear responsibility systems and emergency plans to ensure a rapid response in case of abnormalities.
c. Establish experience sharing mechanisms to promptly summarize and disseminate fault handling experiences.
Practice proves that sound operating procedures and maintenance management can reduce unplanned downtime of centrifugal pumps by over 70%, significantly improving equipment reliability and service life.
4. Response Measures for Emergency Situations
Despite various preventive measures, centrifugal pump cavitation may still occur under special circumstances. In such cases, emergency response measures are needed to minimize losses:
A. Rapid Identification and Shutdown:
a. If signs of cavitation such as abnormal noise, increased vibration, or a sudden drop in discharge pressure are detected, the pump should be shut down immediately for inspection.
b. For critical equipment, emergency stop buttons can be installed to halt the pump immediately upon detecting abnormalities.
c. Do not repeatedly start the pump before confirming and eliminating the cause of cavitation, to avoid exacerbating damage.
B. Emergency Cooling Measures:
a. If the pump body is found to be overheated but serious damage has not yet occurred, external cooling measures can be taken, such as wrapping the pump body with wet cloths or applying slight water spray cooling (taking care to avoid electrical components).
b. Do not immediately cool overheated bearings with cold water, to prevent damage from thermal stress.
C. Restoring Normal Liquid Supply:
a. Check and clear blockages in the inlet pipeline.
b. For insufficient liquid level, promptly replenish the water source or lower the pump's installation height.
c. Check and repair air leakage points in the pipeline system.
D. Special Monitoring After Restart:
a. When restarting the pump after a cavitation event, pay special attention to whether the seal is leaking, if the bearing temperature is normal, and if vibration is within allowable limits.
b. Only resume normal operation after confirming all parameters are normal.
c. It is recommended to increase the frequency of inspection rounds temporarily to ensure stable equipment operation.
E. Damage Assessment and Repair:
a. Pumps that have experienced severe cavitation should undergo a comprehensive inspection to assess the extent of damage.
b. Replace damaged components if necessary, such as mechanical seals, seal rings, and bearings.
c. Inspect the impeller and pump casing for damage caused by cavitation.
Through timely and effective emergency handling, losses caused by cavitation can be minimized. Statistics show that reasonable emergency measures can reduce equipment recovery time by over 50% in emergency situations, while also reducing the risk of secondary damage.
Read More